Browsing by Autor "Willam Murillo Borda"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item type: Item , Bloques prensados de suelo-cemento como alternativa ecológica frente a los ladrillos tradicionales de arcilla cocida(2019) Joaquín Humberto Aquino Rocha; Nataly Andrea Zapata Ampuero; Marialaura Herrera Rosas; Willam Murillo Borda; Giovanni Galindo AñezLa producción de ladrillos de arcilla cocida de forma artesanal todavía es realizada y ampliamente extendida, especialmente en países en vías de desarrollo; sin embargo, esta práctica consume varios recursos naturales y genera emisiones dióxido de carbono (CO), afectando negativamente al medio ambiente y la comunidad. En este sentido, el objetivo del presente estudio es evaluar las características de los bloques de suelo-cemento como una alternativa ecológica, comparándolos con los ladrillos tradicionales de arcilla cocida. Para tal motivo, se fabricaron un total de 105 bloques de suelo-cemento con diferentes contenidos de cemento (2%, 4%, 6%, 8% y 10%), lo cuales fueron sometidos a diferentes ensayos: resistencia a la compresión, absorción y durabilidad. Los resultados muestran que los bloques con 8% y 10% de cemento presentan las mejores características e incluso pueden ser utilizados para construcciones a partir de los 7 días desde su fabricación; no obstante, los bloques de 4% y 6% de cemento también pueden ser utilizados, pero a partir de los 28 días, tiempo donde desarrollan las características recomendadas.Item type: Item , Comparative Evaluation of Grids for the Detection of Internal Defects in Concrete Using Ultrasonic Pulse Velocity: Experimental Approach(American Society of Civil Engineers, 2025) Joaquín Humberto Aquino Rocha; Willam Murillo Borda; Marialaura Herrera Rosas; Nahúm Gamalier Cayo ChilenoThis study evaluates the efficacy of ultrasonic pulse velocity (UPV) testing in detecting internal defects in concrete through an experimental comparison of various measurement grid configurations and concrete compressive strengths. Concrete blocks measuring 60×60×20 cm were fabricated with simulated internal defects created using polystyrene plates. UPV testing was performed in direct transmission mode to identify and quantify defective areas. Measurement grids with densities of 2.5×2.5 cm, 5×5 cm, and 10×10 cm were utilized, and three compressive strength levels were analyzed: 21 MPa (C21), 25 MPa (C25), and 30 MPa (C30). The findings reveal that the 2.5×2.5 cm grid is the most effective for detecting defects, offering an accurate differentiation of internal variations within the concrete, particularly in higher-strength mixtures. In contrast, less dense grids exhibited greater variability in measurements and reduced sensitivity to smaller defects (6.25 cm2). The selection of grid density should carefully balance the need for precision with practical constraints, such as time and resources. Complementing UPV testing with other nondestructive testing (NDT) methods is recommended to achieve a more comprehensive evaluation of concrete integrity.