CONTAMINACIÓN DE SUPERFICIE DE CELULARES PORTADOS EN LA UNIDAD DE TERAPIA INTENSIVA PEDIÁTRICA Y LA UNIDAD DE NEONATOLOGÍA

dc.contributor.authorMedina Dips, Noelia
dc.contributor.authorMejía Salas, Héctor
dc.coverage.spatialBolivia
dc.date.accessioned2026-03-23T15:32:12Z
dc.date.available2026-03-23T15:32:12Z
dc.date.issued2018
dc.descriptionVol. 24, No. 2
dc.description.abstractIntroducción: Los teléfonos celulares son utilizados por el personal de salud frecuentemente, antes o durante la revisión médica del paciente, dicho personal debería cumplir con las normas de bioseguridad, inclusive con estos dispositivos. Objetivo: Determinar el grado de contaminación de la superficie de celulares portados por el personal de salud y luego de una intervención, verificar la reducción de la contaminación en la Unidad de Terapia Intensiva Pediátrica (UTIP) y la Unidad de Neonatología del Hospital del Niño "Dr. Ovidio Aliaga Uría". Método: Ensayo clínico antes y después, simple ciego. En la primera fase se realizó cultivo de las superficies de los teléfonos celulares y se aplicó una encuesta sobre el uso de estos dispositivos. En la segunda fase, se realizó la intervención, con áreas de limpieza para celulares, efectuando una nueva toma de muestra. Resultados: Se incluyó a todo el personal de salud de UTIP y Neonatología. El 72% utiliza celulares dentro de su Unidad. En la Fase 1, en el 69% de los dispositivos de la Unidad de Neonatología, existía contaminación, 42% en UTIP, 52,1 %en ambas Unidades. En la Fase 2, después de la intervención, un 50% en Neonatología, 10% en UTIP y 23,9% en ambas Unidades, el microorganismo mayormente hallado fue E. coli cepa BLEE. El RR de posibilidad de contaminación después de la intervención fue de 0,46 (IC 95% 0,25 - 0,82); en la Unidad de Neonatología redujo la contaminación 19% y en UTIP 33%. Conclusión: Existe contaminación en la superficie de los teléfonos celulares utilizados por el personal de salud de las Unidades estudiadas, esta es posible reducirla con intervenciones sencillas como la limpieza de dispositivos.es
dc.description.abstractIntroduction: Cell phones are used by health personnel on a daily basis, before or during patient's medical examination; these personnel should follow the biosafety norms, even with these devices. Objective: Determine the degree of cell surface contamination carried by the health personnel and after an intervention, verify the reduction of contamination in the Pediatric Intensive Care Unit (PICU) and the Neonatal Unit of the "Ovidio Aliaga Uría" Children's Hospital in La Paz, Bolivia. Method: Clinical trial before and after, single blind. In the first phase, sampling was done by swabbing the surfaces of cell phones for culture, while a survey about the use of these devices was applied. In the second phase, the intervention was performed, with cleaning areas for cell phones, and a new sample was taken afterwards. Results: All health personnel from PICU and Neonatology Unit were included. 72% use their cell phone in their Unit. In Phase 1, 69% of cell phones were contaminated in the Neonatology Unit, 42% in the PICU, 52.1% in both Units and in Phase 2, 50% in Neonatology, 10% in PICU, with 23.9% in both Units, the microorganism found most frequently was E. coli strain ESBL. The RR of possibility of contamination after the intervention was 0.46 (95% CI 0.25-0.82); in the Neonatology Unit it reduced contamination by 19% and in the PICU by 33%. Conclusion: Contamination was detected on the surface of cell phones used by the health personnel of the Units involved, it is possible to reduce it with simple methods such as cleaning devices.en
dc.identifier.urihttp://www.scielo.org.bo/scielo.php?script=sci_arttext&pid=S1726-89582018000200006&tlng=es
dc.identifier.urihttps://andeanlibrary.org/handle/123456789/93190
dc.language.isoes
dc.publisherRev. Méd. La Paz
dc.relationhttp://www.scielo.org.bo/pdf/rmcmlp/v24n2/v24n2_a06.pdf
dc.relation.ispartofRev. Méd. La Paz
dc.sourceSciELO Bolivia
dc.subjectTeléfono celular
dc.subjectcontrol de infecciones
dc.subjectcontaminación bacteriana
dc.subjectCell phone
dc.subjectinfection control
dc.subjectbacterial contamination
dc.titleCONTAMINACIÓN DE SUPERFICIE DE CELULARES PORTADOS EN LA UNIDAD DE TERAPIA INTENSIVA PEDIÁTRICA Y LA UNIDAD DE NEONATOLOGÍA
dc.title.alternativeSURFACE CONTAMINATION OF CELL PHONES CARRIED IN THE PEDIATRIC INTENSIVE CARE UNIT AND THE NEONATOLOGY UNIT
dc.typeArtículo Científico Publicado

Files