CORRELACIÓN DE VALORES β-HCG Y ULTRASONOGRAFÍA INTRAOPERATORIA EN EMBARAZO ECTÓPICO

dc.contributor.authorCrispin Nina, Deyssi
dc.contributor.authorDurán Calle, Juan José
dc.coverage.spatialBolivia
dc.date.accessioned2026-03-23T15:44:43Z
dc.date.available2026-03-23T15:44:43Z
dc.date.issued2020
dc.descriptionVol. 26, No. 1
dc.description.abstractIntroducción: El diagnóstico del embarazo ectópico puede no resultar fácil y se debe realizar con rapidez y seguridad, pues una demora puede conllevar a la ruptura, la hemorragia y poner en peligro la vida de la paciente. Objetivo: Determinar el grado de correlación de valores de β-hCG y ultrasonografía con los hallazgos intra-operatorios de pacientes con diagnóstico de embarazo ectópico en el servicio de Ginecología y Obstetricia del Hospital Municipal Boliviano Holandés. Material y métodos: Estudio descriptivo transversal y retrospectivo. Se estudiaron 115 pacientes con diagnóstico de embarazo ectópico, internadas en el Servicio de Ginecología y Obstetricia del Hospital Municipal Boliviano Holandés, durante el periodo 2010 - 2014. Resultados: La población con mayor frecuencia afectada, es de 20 a 30 años de edad (88,7%). La mayor cantidad de población, se observó durante el año 2014 (47%). La validez de los hallazgos ultrasonográficos es de: Sensibilidad = 98,2% y Especificidad = 75%. La seguridad de los hallazgos ultrasonográficos es de: Valor Predictivo Positivo = 99,1% y Valor Predictivo Negativo = 60%. La validez de los hallazgos ultrasonográficos combinado con la cuantificación sérica de β-hCG es de: Sensibilidad = 99,1% y Especificidad = 100%. La seguridad de los hallazgos ultrasonográficos combinado con la cuantificación sérica de β-hCG es de: Valor Predictivo Positivo = 100% y Valor Predictivo Negativo = 80%. Conclusión: El test diagnóstico ultrasonográfico combinado con la cuantificación sérica de β-hCG tiene mayor validez y seguridad que el test diagnóstico ultrasonográfico solo.es
dc.description.abstractIntroduction: The diagnosis for ectopic pregnancy may be difficult, and must be carried out quickly and safely since a delay can lead to rupture, bleeding and endanger the life of the patient. Objective: To determine the correlation degree of β-hCG levels and ultrasonography with the intra-operative findings of patients with ectopic pregnancy diagnosis in the Gynecology and Obstetrics Service at Hospital Municipal Boliviano Holandés. Material and methods: Descriptive, cross-sectional and retrospective study that included 115 patients with ectopic pregnancy diagnosis, and admitted in the Obstetrics and Gynecology Service at Hospital Municipal Boliviano Holandés during the period 2010-2014. Results: The most frequently affected population was 20 to 30 years old (88.7%). Most of the cases were observed during 2014 (47%). Validity of ultrasound findings reflected 98.2% of sensitivity and 75 % of specificity. Safety of ultrasound findings reflected Positive Predictive Value of 99.1 % and Negative Predictive Value of 60 %. Validity of ultrasound findings combined with β-hCG serum quantification displayed a sensitivity of 99.1 % and specificity of100%. Safety of ultrasound findings combined with β-hCG serum quantification displayed a Positive Predictive Value of 100 % and Negative Predictive Value of 80 %. Conclusions: The ultrasonographic diagnostic test combined with the β-hCG serum quantification has better validity and safety than the ultrasonographic test alone.en
dc.identifier.urihttp://www.scielo.org.bo/scielo.php?script=sci_arttext&pid=S1726-89582020000100003&tlng=es
dc.identifier.urihttps://andeanlibrary.org/handle/123456789/94399
dc.language.isoes
dc.publisherRev. Méd. La Paz
dc.relationhttp://www.scielo.org.bo/pdf/rmcmlp/v26n1/v26n1_a03.pdf
dc.relation.ispartofRev. Méd. La Paz
dc.sourceSciELO Bolivia
dc.subject-hCG
dc.subjectultrasonografía
dc.subjectembarazo ectópico
dc.subjectvalidez
dc.subjectseguridad
dc.subject-hCG
dc.subjectultrasonography
dc.subjectectopic pregnancy
dc.titleCORRELACIÓN DE VALORES β-HCG Y ULTRASONOGRAFÍA INTRAOPERATORIA EN EMBARAZO ECTÓPICO
dc.title.alternativeCORRELATION OF β-HCG LEVELS AND INTRA-OPERATIVE ULTRASONOGRAPHY IN ECTOPIC PREGNANCY
dc.typeArtículo Científico Publicado

Files