Iodo radiactivo para uso terapéutico, producido por le Ciclotrón

dc.contributor.authorMelissa Oropeza
dc.contributor.authorGianfranco Spavieri
dc.contributor.authorM. Zambelli
dc.coverage.spatialBolivia
dc.date.accessioned2026-03-22T17:44:59Z
dc.date.available2026-03-22T17:44:59Z
dc.date.issued1994
dc.description.abstractIn this paper we explore the possibility of producing iodine isotopes, with a low-medium energy electron, to be used for medical therapy. The analysis of the spectrum of the emitted radiation suggests that the cyclotron produced 1261 may be used to substitute the nuclear reactor produced 1311. One of die advantages of 1261 is that the caracteristic gamma emission makes it easier to monitor with SPECT techniques. The presence of 13 + emission makes possible also tile monitoring with Positron Emission Tomography (PET)
dc.identifier.urihttps://andeanlibrary.org/handle/123456789/66018
dc.language.isoes
dc.sourceUniversidad de Los Andes
dc.subjectCyclotron
dc.subjectPositron emission tomography
dc.subjectPhysics
dc.subjectNuclear medicine
dc.subjectPositron emission
dc.subjectRadiochemistry
dc.subjectNuclear physics
dc.subjectMedical physics
dc.titleIodo radiactivo para uso terapéutico, producido por le Ciclotrón
dc.typearticle