Final report on regional key comparison SIM.M.FF-K4: Volume of liquids at 20 L and 100 mL

dc.contributor.authorRoberto Arias
dc.contributor.authorManuel Maldonado
dc.contributor.authorJohn D. Wright
dc.contributor.authorTanisha Wallace
dc.contributor.authorS. L. Rodríguez-Reyna
dc.contributor.authorOrlando Pinzón
dc.contributor.authorA Castillo Morales
dc.contributor.authorMaria José Vega
dc.contributor.authorClaudia Santo
dc.contributor.authorFernando Kornblit
dc.coverage.spatialBolivia
dc.date.accessioned2026-03-22T17:08:49Z
dc.date.available2026-03-22T17:08:49Z
dc.date.issued2010
dc.description.abstractAt its meeting in October 2006 in Queretaro, Mexico, the Interamerican Metrology System (SIM) Technical Committee for Fluid Flow (TCFF) approved a Regional Key Comparison for Volume of Liquids at 20 L and 100 mL, to be piloted by the national metrology institute of Mexico (CENAM). The objective of this comparison was to demonstrate the degree of equivalence of the volume measurement standards held at national measurement institutes (NMIs) and to provide supporting evidence for the Calibration and Measurement Capabilities (CMCs) claimed by the participating laboratories in the Americas. During the comparison, one of the pycnometers suffered irreversible damage, and degrees of equivalence for volume at 100 mL were calculated using the results obtained with one single pycnometer (TS 03.04.04). Conclusions are as follows: The transfer standards for SIM.M.FF-K4 exhibited global good performance all the way along, both in terms of stability and repeatability. Degrees of equivalence have been produced for volumes at 20 L and at 100 mL. The best estimation of the measurands, as reported by the participants, shows a general agreement better than ±0.0070% for volume of liquids at 100 mL and 20 L. It is advisable to review the uncertainty analysis of some participants. New CMC entries for some NMIs should take into account the information presented in this Report. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
dc.identifier.doi10.1088/0026-1394/47/1a/07002
dc.identifier.urihttps://doi.org/10.1088/0026-1394/47/1a/07002
dc.identifier.urihttps://andeanlibrary.org/handle/123456789/62443
dc.language.isoen
dc.publisherIOP Publishing
dc.relation.ispartofMetrologia
dc.sourceNational Metrology Center
dc.subjectKey (lock)
dc.subjectVolume (thermodynamics)
dc.subjectMaterials science
dc.subjectMathematics
dc.subjectStatistics
dc.titleFinal report on regional key comparison SIM.M.FF-K4: Volume of liquids at 20 L and 100 mL
dc.typearticle

Files