Pruebas con hidrotalcita patente "WO2010/008262 AL" para el tratamiento de agua acidulada
| dc.contributor.author | Malavé Gómez, Adonis A. | |
| dc.contributor.author | Merchán Bravo, Madelaine S. | |
| dc.contributor.author | Quevedo Pinos, Olga L. | |
| dc.contributor.author | Revelo Ramírez, Willan E. | |
| dc.coverage.spatial | Bolivia | |
| dc.date.accessioned | 2026-03-23T16:19:24Z | |
| dc.date.available | 2026-03-23T16:19:24Z | |
| dc.date.issued | 2024 | |
| dc.description | Vol. 41, No. 2 | |
| dc.description.abstract | Se usó la patente "WO 2010/008262 AL" con hidrotalcita en aguas aciduladas de referencia, control y de baterías de submarinos de la Armada del Ecuador. El objetivo fue reducir los niveles de iones sulfato, y el DQO en el agua desechada para su descarga segura. La metodología fue ajustada a las condiciones y posibilidades de materiales, equipos, y reactivos. De manera estequiométrica se determinó la cantidad requerida de Mg(OH)2 de 40,2 g frente a los 4,86 g de Al2(SO4)3. La síntesis de hidrotalcita para el tratamiento de aguas aciduladas se determinó con tres gramos de éstas, activadas a 450 °C. Se pudieron neutralizar 200 ml de agua acidulada variando el pH de 0 - 1 a 7 - 8 con un DQO no detectable, la presencia de iones sulfatos entre 14600 - 17000 mg/l demuestró que no se lograron mover estos iones de las aguas de referencia y control. | es |
| dc.description.abstract | Tests with hydrotalcite patent "WO2010/008262 AL" for the treatment of acidulated water. The patent "WO 2010/008262 AL" was used with hydrotalcite in acidified reference, control and submarine battery waters of the Ecuadorian Navy. The objective was to reduce the levels of sulfate ions and DQO in the waste water for safe discharge. The methodology was adjusted to the conditions and possibilities of materials, equipment, and reagents. In a stoichiometric manner, the required amount of Mg(OH)2 was determined to be 40.2 g compared to 4.86 g of Al2(SO4)3. The synthesis of hydrotalcite for the treatment of acidified water was determined with three grams of these, activated at 450 °C. 200 ml of acidulated water could be neutralized by varying the pH from 0 - 1 to 7 - 8, with a non-detectable DQO. The presence of sulfate ions between 14,600 - 17,000 mg/l demonstrated that these ions were not able to move from the reference and control waters. | en |
| dc.identifier.doi | 10.34098/2078-3949.41.2.1 | |
| dc.identifier.issn | 0250-5460 | |
| dc.identifier.uri | https://doi.org/10.34098/2078-3949.41.2.1 | |
| dc.identifier.uri | https://andeanlibrary.org/handle/123456789/97792 | |
| dc.language.iso | es | |
| dc.publisher | Rev. Bol. Quim | |
| dc.relation.ispartof | Rev. Bol. Quim | |
| dc.source | SciELO Bolivia | |
| dc.subject | Hydrotalcite | |
| dc.subject | Acidulated water | |
| dc.subject | Batteries | |
| dc.subject | Neutrality | |
| dc.subject | Hidrotalcita | |
| dc.subject | Agua acidulada | |
| dc.subject | Baterías | |
| dc.subject | Neutralidad | |
| dc.title | Pruebas con hidrotalcita patente "WO2010/008262 AL" para el tratamiento de agua acidulada | |
| dc.type | Artículo Científico Publicado |