Sensibilidad y especificidad de pruebas inmunocromatográficas utilizadas en el nuevo algoritmo de diagnóstico de VIH en Bolivia

dc.contributor.authorMartínez-Oliva, Brenda Gisela
dc.contributor.authorMontaño-Valenzuela, Karen Jimena
dc.contributor.authorRodriguez-Herbas, Patricia
dc.contributor.authorFlores-León, Amilcar Alejandro
dc.contributor.authorGrados-Torrez, Ricardo Enrique
dc.coverage.spatialBolivia
dc.date.accessioned2026-03-23T15:34:44Z
dc.date.available2026-03-23T15:34:44Z
dc.date.issued2018
dc.descriptionVol. 41, No. 2
dc.description.abstractObjetivo: evaluar la sensibilidad y especificidad de dos pruebas rápidas utilizadas en el nuevo algoritmo de diagnóstico de VIH en Bolivia, Alere DetermineTM HIV 1/2 como prueba de tamizaje y Uni-GoldTM HIV como prueba confirmatoria. Métodos: estudio descriptivo, no experimental. Se utilizaron 60 muestras de suero provenientes de diferentes establecimientos de salud de Cochabamba con resultados reactivos para VIH, enviadas a LABIMED desde enero a junio de 2016 para confirmación. Las 60 muestras (27 positivas y 33 negativas para VIH) fueron procesadas con Alere DetermineTM HIV 1/2 y Uni-GoldTM HIV. Resultados: alere DetermineTM HIV 1/2 presentó una sensibilidad del 100% y una especificidad del 54,5%. Uni-GoldTM HIV reportó una especificad del 97% y una sensibilidad del 92,6%. Conclusiones: la sensibilidad de Alere Determine TM HIV 1/2 cumplió con el criterio del Ministerio de Salud y Deportes de Bolivia (Prueba rápida de tamizaje debe tener una sensibilidad ≥ 99,8%). La especificidad de Uni-GoldTM HIV en este estudio no alcanzó el criterio de especificidad del Ministerio (Prueba rápida de confirmación debe tener una especificidad ≥ 99,9%).es
dc.description.abstractObjective: to evaluate the sensitivity and specificity of the two rapid tests used in the new algorithm of HIV diagnosis in Bolivia, Alere DetermineTM HIV 1/2 as a screening test and Uni-Gold TM HIV as a confirmatory test. Methods: this is a descriptive and non-experimental study. Sixty serum samples were used with reactive results for HIV from different health establishments in Cochabamba sent to LABIMED from January to June 2016 for HIV confirmation. The 60 samples (27 positive and 33 negative for HIV) were tested with Alere DetermineTM HIV 1/2 and Uni-GoldTM HIV. Results: Alere DetermineTM HIV 1/2 presented a sensitivity of 100 % and a specificity of 54,5%. Uni-GoldTM HIV reported a sensitivity of 92,6% and a specificity of 97%. Conclusions: the sensitivity of Alere Determine TM HIV 1/2 fulfilled the criteria of the Ministry of Health and Sports of Bolivia (rapid screening test must have a sensitivity ≥ 99.8%). The specificity of Uni-GoldTM HIV in this study did not fulfill the Ministry's specificity criterion (rapid confirmation test must have a specificity ≥99.9%).en
dc.identifier.urihttp://www.scielo.org.bo/scielo.php?script=sci_arttext&pid=S1012-29662018000200002&tlng=es
dc.identifier.urihttps://andeanlibrary.org/handle/123456789/93435
dc.language.isoes
dc.publisherGac Med Bol
dc.relationhttp://www.scielo.org.bo/pdf/gmb/v41n2/v41n2a2.pdf
dc.relation.ispartofGac Med Bol
dc.sourceSciELO Bolivia
dc.subjectanticuerpos contra VIH
dc.subjectdiagnóstico temprano
dc.subjectserodiagnóstico del SIDA
dc.subjectpruebas inmunológicas
dc.subjectsensibilidad y especificidad
dc.subjectalgoritmo
dc.subjectHIV antibodies
dc.subjectearly diagnosis
dc.subjectAIDS serodiagnosis
dc.subjectinmunologic tests
dc.subjectsensitivity and specificity
dc.subjectalgorithm
dc.titleSensibilidad y especificidad de pruebas inmunocromatográficas utilizadas en el nuevo algoritmo de diagnóstico de VIH en Bolivia
dc.title.alternativeSensitivity and specificity of inmunocromatographic tests used in the new algorithm of HIV diagnosis in Bolivia
dc.typeArtículo Científico Publicado

Files