Harnessing of geothermal energy for a greenhouse in Ecuador employing a heat pump: design, construction, and feasibility assessment.

dc.contributor.authorChiriboga, Gonzalo
dc.contributor.authorCapelo, Santiago
dc.contributor.authorBunces, Pablo
dc.contributor.authorGuzmán, Carla
dc.contributor.authorCepeda, Jonathan
dc.contributor.authorGordillo, Gilda
dc.contributor.authorMontesdeoca, Diego E
dc.contributor.authorCarvajal C, Ghem
dc.coverage.spatialBolivia
dc.date.accessioned2026-03-24T15:03:48Z
dc.date.available2026-03-24T15:03:48Z
dc.date.issued2021
dc.descriptionVol. 7, No. 12, pp. e08608
dc.description.abstractGlobally, the greenhouses' farming area comprises 500 000 ha, and they efficiently produce more than half of the vegetables consumed around the world. Nevertheless, high-yield crops tend to be incredibly energy-intensive. This study proposes designing and building a coupled geothermal heat pump for a 470 m2 greenhouse in the Andean zone conditions addressing a requirement of 15 °C at night and 30 °C during the day. Firstly, the study determined the energy potential of the solar and geothermal sources employing actual measurements and contrasting the results with theoretical models. Then, it developed an energy balance in the greenhouse to size the geothermal heat pump using the vapor compression cycle. Finally, the comprehensive system was built and evaluated through the Leveled Cost of Heat (LCOH). The operation requires a potential of 29.56 and 65.76 kW for heating and cooling; this is technically feasible when running the system with a heating flow driven by an optimized temperature ramp of 1.64 °C h-1. Also, the capacity factor (CF) shows that a lifespan between 12 to 14 years is required to reach acceptable LCOH when CF is as low as 0.45. Financially, it is necessary to foster customs exemptions to make it competitive versus more traditional sources such as electricity and LPG since the main components of the heat pump and the geothermal exchanger are not produced locally and represent nearly 70 % of the upfront costs.eng
dc.description.sponsorshipCentral University of Ecuador, Chemical Engineering Faculty, Jerónimo Ritter S/N and Bolivia Quito, Ecuador. | Central University of Ecuador, Chemical Engineering Faculty, Jerónimo Ritter S/N and Bolivia Quito, Ecuador. | Central University of Ecuador, Chemical Engineering Faculty, Jerónimo Ritter S/N and Bolivia Quito, Ecuador.
dc.identifier.doi10.1016/j.heliyon.2021.e08608
dc.identifier.issn2405-8440
dc.identifier.otherPMID:35005271
dc.identifier.urihttps://doi.org/10.1016/j.heliyon.2021.e08608
dc.identifier.urihttps://andeanlibrary.org/handle/123456789/100983
dc.language.isoeng
dc.relation.ispartofHeliyon
dc.sourcePubMed
dc.subjectCapacity factor
dc.subjectEcuador
dc.subjectGeothermal conditioning
dc.subjectGreenhouse
dc.subjectHeat pump
dc.subjectLCOH
dc.titleHarnessing of geothermal energy for a greenhouse in Ecuador employing a heat pump: design, construction, and feasibility assessment.
dc.typeArtículo Científico Publicado

Files