Tomografía por emisión de positrones. Una nueva técnica para medición de volúmenes y fracción de expulsión del ventrículo izquierdo
| dc.contributor.author | Erick Alexánderson‐Rosas | |
| dc.contributor.author | Nilda Espínola‐Zavaleta | |
| dc.contributor.author | Alondra Flores-García | |
| dc.contributor.author | Rodrigo Escalante-Armenta | |
| dc.contributor.author | Carlo A. Sánchez-Montaño | |
| dc.contributor.author | Jessy Steve Masso-Bueso | |
| dc.contributor.author | Maximiliano Flores-Flamand | |
| dc.contributor.author | Oscar A Pérez-Orpinel | |
| dc.coverage.spatial | Bolivia | |
| dc.date.accessioned | 2026-03-22T18:07:52Z | |
| dc.date.available | 2026-03-22T18:07:52Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | The left ventricular ejection fraction (LVEF) is a parameter that reflects the myocardial systolic function. Its measurement is of great importance to establish the diagnosis, treatment and prognosis of different cardiovascular diseases. There are several non-invasive methods such as echocardiography, magnetic resonance imaging, Gated-SPECT for the measurement of ventricular volumetric and the ejection fraction of the left ventricle. Objective: The objective of this study was to determine the normal values of left ventricular volumes and LVEF using Gated-PET-13N-Amonia in Mexican population. Material and methods: We included patients with normal Gated-PET 13 N-Ammonium myocardial perfusion study. Left ventricular volumes and ejection fraction were obtained. Images were analyzed in QPS-QGS Cedars Sinai . The variables were expressed in mean and standard deviation. Results: A total of 78 patients were included. The end-diastolic volume (EDV) at rest was of 84.928.2 mL, the end-systolic volume (ESV) 28.220.1, the stroke volume (SV) 56.812.8 mL and the LVEF 68.79.1%. The stress EDV was of 96.331.7 mL, the stress ESV 32.121.7 mL, the SV 6413.9 mL and the LVEF 68.38.75%. Conclusion: The measurement of left ventricular volumes and ejection fraction obtained by the PET 13 N-Ammonium perfusion study is feasible and should be considered as an additional diagnostic tool. | |
| dc.identifier.doi | 10.35366/91808 | |
| dc.identifier.uri | https://doi.org/10.35366/91808 | |
| dc.identifier.uri | https://andeanlibrary.org/handle/123456789/68292 | |
| dc.language.iso | es | |
| dc.relation.ispartof | CIU Cardiac Image Updated | |
| dc.source | Universidad La Salle | |
| dc.subject | Humanities | |
| dc.subject | Medicine | |
| dc.subject | Philosophy | |
| dc.title | Tomografía por emisión de positrones. Una nueva técnica para medición de volúmenes y fracción de expulsión del ventrículo izquierdo | |
| dc.type | article |